Contents of this source
Why countably many Radon probes cannot recover full original capacity
The exact energy-normalized capacity in the preceding section is controlled by one original Radon measure. Its null ideal is therefore different in nature from the full original tester capacity. The following all-dimensional example proves that the distinction cannot in general be removed by replacing that measure by a countable family. This is a counterexample within the allowed background class, not a restriction on the backgrounds of the positive theorems.
Fix integers and a real number . Work over the original finite extension with its unchanged absolute value. On put If , . The current is an original symmetric strongly positive, hence middle-positive, separately closed current of degree . It extends across the closed box. Taking a larger compact polyannulus supplies the precise strict-box hypothesis. In particular no original field, absolute value or boundary convention has changed.
For , denote by the original Gauss point of with radii . These points exist for arbitrary real , without a value-group or algebraic-closure assumption. The map is a continuous injection. Define on the whole original domain
Lemma (A full original normalized tester at every Gauss point). The function is an original continuous classical psh function with on . Its full original top current is Consequently These are assertions for the unrestricted original normalized tester family on the whole , not for a fixed finite presentation class.
Status: DIRECT_COROLLARY of the frozen original bounded BT calculus, its integration-current projection formula, and the elementary toric convex PL calibration. The explicit calibration below fixes its normalization. It is not a new instance of the arbitrary-background analytic relation quotient. The exact frozen torus locator is R6 sections/capacity_gauss_convex_reduction.tex, eq:r6-toric-convex-laplacian, whose source SHA256 is 2ab2277e81fdad829815f0fe30dc6e921f1d0d8c1fb70de71b718fe4f9d83e38. It explicitly distinguishes the all-original-test toric identity from a mere pushforward identity. The original real-radius calibration is also recorded in R6 sections/capacity_laminar_graphs.tex, eq:r6-arbitrary-radius-capacity. The targeted nested archive and source checks are retained in checks/targeted_r6_calibration.json.
Proof. The function in (CM2) is the pullback of a convex real PL function under an actual original unit moment. Convex smoothing and the frozen bounded uniform convergence theorem make it original classical psh. For all , , which proves its normalization.
On the coordinate subtorus , the subgradient at is the cross-polytope Here is a direct smooth calculation that also checks support on the full original test sheaf. Put Then on the entire real moment cube. The Hessian of is the positive definite covariance matrix of the affinely spanning vectors with strictly positive exponential weights. The map is a diffeomorphism onto the interior of : for any interior , the strictly convex function is coercive, since the support function of exceeds by a positive multiple of . It has one critical point; the positive Hessian gives the smooth inverse. Change of variables therefore gives Since , its finite measure converges weakly to . This follows directly by dominated convergence after the displayed change of scale; no general Monge–Ampere continuity theorem for unrestricted unbounded potentials is involved.
For completeness the elementary original torus integration formula has its full-test meaning here. At any point of the -torus outside its Gauss skeleton, some Laurent polynomial satisfies . This strict inequality persists on an ordinary neighborhood. At each point of that neighborhood at least two monomials attain the displayed maximum, by the ultrametric inequality. Its moment image thus lies in the tropical hypersurface of , of real dimension at most . Every smooth moment-pulled form vanishes there by the definition of original CLD pullback. The resulting smooth top measure is therefore carried by the original Gauss skeleton. On that skeleton canonical torus tropical integration has weight one and gives, for every compact original smooth scalar test , Skeleton support is what makes this an identity on all original tests, not merely a statement about the moment pushforward. The normalization agrees with the unit simplex radial shell (PO6). Now (CM5b), continuity of and the uniform bounded-potential convergence theorem give . For , the frozen integration-current projection formula applies this same calculation on and pushes the Dirac measure into the original ambient . Thus all original tests and all actual moment refinements are retained in (CM3). Using as a permitted normalized tester gives the first inequality in (CM4); monotonicity of the ordinary-open outer regularization gives the second. ◻
Theorem (No countable Radon family controls the full capacity-null ideal). For the allowed data (CM1), let be any countable family of positive Radon measures on . There is one original point , lying in a fixed ordinary relatively compact window independent of the measures, such that Hence the full original outer-capacity-null ideal cannot be characterized as the simultaneous null ideal of countably many positive Radon measures. In particular, there is no single Radon measure and function with such that for every Borel subset of that window.
Status: NEW_PROVED as an all-dimensional obstruction to the proposed countable Radon control mechanism. The proposed universal equivalence and (CM7) are FALSE.
Proof. Choose the fixed window and the compact uncountable Gauss set Each is finite on . A finite measure has at most countably many atoms there: for each positive integer , only finitely many atoms have mass at least . Thus the union, over all , of the atoms of in is countable. Choose outside it. All the vanishing assertions in (CM6) follow, while (CM4) gives the strictly positive full capacity. Applying the proposed (CM7) to this singleton would give , a contradiction. ◻
Corollary (Strict null-ideal separation for the parameter energy capacity). In every , choose (CM1) and use the empty parameter tuple in the parameter finite-energy construction. For any one of its allowed probes , there is a Borel singleton such that The same singleton can be chosen simultaneously for any countable family of such probes and their energy-normalized capacities.
Status: NEW_PROVED explicit strict separation, using the already proved exact null ideal in (PC12).
Proof. The empty parameter tuple makes conormality automatic; it does not change the current . Apply (CM6) to the finite positive Radon measure , or to the countable family of these measures. Formula (PC12) gives precisely the two zeros in (CM9), whereas (CM4) gives its last inequality. All resulting capacities still use their explicitly different admissible families. No comparison of those families has been suppressed. ◻
What this does not contradict.
The geometry-only probe detects specified normal or Jensen defects by closedness and two-sided original test perturbations; it was never asserted to dominate every normalized source measure. Countable cofinality of original smooth test stages is likewise not countable cofinality of all normalized nonlinear tester measures. The band formulas choose their essential suprema for each fixed set and parameter control; they do not claim a single countable list detecting every analytic set. Thus (CM6) is an obstruction to a particular route to unrestricted capacity, not a counterexample to its Choquet regularity or to the analytic PS/PL relation quotient.